Table of
Contents
Windows 2000 SP4
Windows XP SP2, Windows XP SP3
Windows Server 2003
Windows Vista, Windows
Windows
Server 2008
Windows
x64-bit platform
Installation requires administrator’s privileges.
New
Features &
Enhancements
New DBCS conversion (v8.51.02)
The
QRCode and DataMatrix barcodes now use direct encoding in DBCS instead of using
the UnicodeToDBCS formula.
New OCX field (v8.51.02)
This new object type allows you to use a third-party OCX component inside
your label.
New formulas (v8.51.02)
New formulas are now available:
Week (calculate week number ISO8601), Extract (extract string from a string),
ReplaceString (replace string occurrence(s) with another string)
Space correction for DataMatrix (v8.51.02)
This option allows you to provide space correction between barcode
elements.
This can be useful for inkjet printing.
New barcode symbologies (v8.51.01)
Chinese sensible code.
ITF14 supports more option for lines/boxes that surround the code.
New GHS pictograms (v8.51.01)
New pictograms based on GHS normalization are added to the Image Gallery.
New Compliance labels (v8.51.01)
New
compliance labels are provided for different areas like Retail, Shipping,
Healthcare, and Automotive.
New barcode symbologies (v8.51)
Code
49, Intelligent Mail (USPS 4-State), ISBN-13, and RSS expanded stacked.
New Formulas (v8.51)
New formulas are now available to allow calculation of the “Best before
date” and “Expiration date” at print time:
BestBefore, DateValue, DateOffset
Database loops (v8.51)
It is now possible to specify the number of times a
set of records should be printed when using a database.
Refresh table lookup at print time (v8.51)
The Refresh table lookup at print time option allows the system to
reevaluate table lookup fields in a document at print time to ensure the most
current information is used.
Silent installation (v8.51)
CODESOFT installation can be run in Silent mode, using
the basic command line "<Path>\Setup.exe" /s /v"/qn
INSTALLLEVEL=150". This command installs CODESOFT in English in the
default folder with all features. For
additional parameters, refer to the TEKLYNX web site or the online help.
Pre-requisite installation (v8.51)
CODESOFT pre-requisites (.NET framework 2.0 SP1,
MDAC 2.8, Adobe Acrobat Reader 8) are now automatically installed if necessary.
Guides (v8.51)
Quick Start Guide and Administrator’s guide are now
directly accessible from the Help menu.
Label Background with image (v8.50.07)
A new Extended tab in Document Properties allows you to define a
background. The user can select an image
and different options to define the background that applies to the current
label.
OCX Component (v8.50.07)
A new OCX control named “Labeling Manager control” is provided. This allows easy integration with Microsoft
Office applications.
Resolution independent
(v8.50.05)
Allows you to design labels that will be
printed identically on different printers (office or thermal printers). To
access to this option, use the command File > Properties > Preview.
New User interface language (v8.50.05)
Romanian language is now available for the
User Interface.
Requery button
(v8.50.05)
A Requery button has been added in the Query
result dialog box. This command runs the query and updates the grid.
Windows graphical emulation (v8.50.04)
Enables you to standardize printing of your
labels irrespective of the printer selected (Thermal printers or Windows
printers). Use the command File > Properties > Preview
to access this option.
Wizard Upgrade tool (v8.50.02)
This tool eases updates from CODESOFT 8 to
CODESOFT 8.5. It allows you to transfer
the settings and files from the previous version to the new one. You can launch it from C:\Program
Files\TKI\8\Common\Tools\WizardUpgrade\UpgradeWizard.exe.
New Wizards (v8.50)
New wizards ease the creation of:
- Documents
- Objects, such as Text, Barcode, and Image
- Variables like Counter, Form, Free, and Date.
The wizards can be activated and deactivated
individually.
Enhanced menu look and feel (v8.50)
A new look and feel for menus is now
available. This is similar to what is available in Office 2003. Two themes are available.
Enhanced Open dialog box (v8.50)
The new open look and feel for the Open dialog
box is used. This provides the left
toolbar icons with direct access to some pre-defined folders.
Enhanced Print dialog box (v8.50)
The Print dialog box now includes several tabs
when expanded.
This will allow you to check, based on current print settings (number of
labels, pages, etc.) whether printing is optimized using the Performance tab.
Text Vertical alignment (v8.50)
This option allows you to define a vertical alignment for text
paragraph. This option is only available
with the Fit to frame option.
Text on any angle (v8.50)
In the Shape Settings
tab, the Polyline shape option allows the user to select any kind of
shape.
This option can be very useful in conjunction with a text art to position text
on any angle.
Label Background definition
(v8.50)
It is now possible to select a label
background without having to use a name based on the stock type/name.
A new Background combo box allows you to
select the EMF/WMF file that will be used as the label background.
The EMF/WMF files need to be published in the C:\Program Files\TKI\8\Common\LFM
directory.
Network licensing (v8.50)
A new range is
available through Network licensing: Runtime.
For License Manager,
the Shared folder is changed.
On
Folder reorganization (v8.50)
Here is the description of the new folder
reorganization.
Samples & Tutorial |
|
Sample
Labels |
<All
Users Profile>\Documents\Teklynx\CODESOFT\Sample\Labels |
Sample
Forms |
<All
Users Profile>\Documents\Teklynx\CODESOFT\Sample\Forms |
Sample
Compliance |
<All
Users Profile>\Documents\Teklynx\CODESOFT\ Sample\Compliance |
Tutorial |
<All
Users Profile>\Documents\Teklynx\CODESOFT\Tutorial |
Common files |
|
Data
files (including databases) |
<All
Users Profile>\Documents\Teklynx\Common\Data |
Describers |
<All
Users Profile>\Documents\Teklynx\Common\DSC |
Specific
Formulas |
<All
Users Profile>\Documents\Teklynx\Common\Formulas |
Image
Gallery |
<All
Users Profile>\Documents\Teklynx\Common\Galleries |
Images
|
<All
Users Profile>\Documents\Teklynx\Common\Images |
Patterns |
<All
Users Profile>\Documents\Teklynx\Common\Patterns |
Queries |
<All
Users Profile>\Documents\Teklynx\Common\Query |
Shapes |
<All
Users Profile>\Documents\Teklynx\Common\Shapes |
Print
files |
<All
Users Profile>\Documents\Teklynx\Print |
Application configuration files |
(Files created
by the application and its tools/add-ons) |
Shared
variables files |
<CommonAppData>\Teklynx\System\Globvar |
Network
printers settings |
<CommonAppData>\Teklynx\System\Printers |
Product config files (user.ini and user.bar) |
<CommonAppData>\Teklynx\System\<ProductRange> |
<ProductRange> is the range of the product;
for example,
Superimposing (v8.10)
This is an optional feature that allows you to superimpose objects to
preserve the readability or physical space on the label. This feature is useful when using a barcode
to prevent any other object from being overlaid on top of it. This feature can be enabled by going to the
General tab of the object’s properties.
Norm GS1 (v8.10)
Choosing to use the GS1 norm enables barcode verifications according to
GS1 (formerly EAN) recommendations.
This new option is available in Tools
> Options dialog box > Others tab. When the option is enabled, it will check
that the barcodes conform to the different requirements of the GS1
normalization, such as narrow bar size, check digit, and human-readable.
RFID (v8.10)
A new RFID button, available on the toolbar, provides a direct link to
the RFID settings.
TKTEXTIL.TTF (v8.10)
New symbols have been added in TKTextil.ttf to fulfill the COFREET
requirements. Refer to the TKTextil.lab
sample file.
Database Manager (v8.10)
The User Interface of the Database Manager has been improved making it
more intuitive and easy to use.
Print by printer resolution (v8.10)
Uses an algorithm independent to the paper format, to send only the
positions and sizes linked to the Windows printer’s resolution.
The current print algorithm adjusts object size and position when you switch,
for instance, from a A4 page to Letter page (on a Windows printer). This is similar to the method used in
Microsoft Word, and the advantage is that the objects are adjusted at print
time so that everything fits on the page/label.
The new print algorithm only uses the printer resolution, which means that
the object’s position and size are fixed, but at print time, you may notice
that some objects are outside the page/label or partially cut.
ActiveX
VC++ and C# ActiveX samples available on CD have been updated to
demonstrate how to use Events.
The
following devices and their associated drivers have been added in this version:
V8.51.02
Manufacturer |
Model |
BRADY |
BRADY
BBP11-24L |
INTERMEC |
EasyCoder PD42 DP (203dpi) EasyCoder PD42 DP (300dpi) EasyCoder PD42 IPL (203dpi) EasyCoder PD42 IPL (300dpi) EasyCoder PD42 FP mode (203dpi) EasyCoder PD42 FP mode (300dpi) PB51 IPL mode (203dpi) |
V8.51.01
Manufacturer |
Model |
BROTHER |
Brother
MW-140BT Brother
MW-260 Brother
QL-1060N Brother
RL-700S |
COGNITIVE |
Cognitive
AdvantageDLX DBD24-2085-xxx Cognitive
AdvantageDLX DBT24-2085-xxx Cognitive
AdvantageDLX DBD42-2085-xxx Cognitive
AdvantageDLX DBT42-2085-xxx |
TALLYGENICOM |
TallyGenicom
7005 DT2 (203dpi) TallyGenicom
7005 DT4 (203dpi) TallyGenicom 7005 TT4 (203dpi) |
ZEBRA |
Zebra
GK420d EPL Zebra
GK420t EPL Zebra
GX420d EPL Zebra
GX420t EPL Zebra
GX430t EPL Zebra
GK420d ZPL Zebra
GK420t ZPL Zebra
GX420d ZPL Zebra
GX420t ZPL Zebra
GX430t ZPL |
VIDEOJET |
VIDEOJET
VJ2310 VIDEOJET
VJ2320 VIDEOJET
VJ2330 |
ICE |
ICE
Torus 126 ICE
Torus 380 ICE Torus
500 |
MARSH |
Marsh 1100 Marsh 2100 Marsh 3100 |
LINX |
Linx IJ350 Linx IJ370 |
V8.50.08
Manufacturer |
Model |
TALLYGENICOM |
TallyGenicom MTP4P TallyGenicom MTP4P EPL TallyGenicom MTP4P ZPL TallyGenicom 7006 DT2 (203dpi) TallyGenicom 7006 DT2 (300dpi) TallyGenicom 7006 DT4 (203dpi) TallyGenicom 7006 DT4 (300dpi) TallyGenicom 7006 TT2 (203dpi) TallyGenicom 7006 TT2 (300dpi) TallyGenicom 7006 TT4 (203dpi) TallyGenicom 7006 TT4 (300dpi) TallyGenicom 7008 DT2 (203dpi) TallyGenicom 7008 DT2 (300dpi) TallyGenicom 7008 DT4 (203dpi) TallyGenicom 7008 DT4 (300dpi) TallyGenicom 7008 TT2 (203dpi) TallyGenicom 7008 TT2 (300dpi) TallyGenicom 7008 TT4 (203dpi) TallyGenicom 7008 TT4 (300dpi) |
BRADY |
Brady
BBP81 200 Brady
BBP81 300 Brady
BBP81 600 |
ZEBRA |
MZ 200 MZ320 Zebra
RW 220 ZPL Zebra
RW 420 ZPL Zebra
RW 220 EPL Zebra
RW 420 EPL Zebra
RW 220 Zebra
RW 420 |
CITIZEN |
CLP-521z CLP-621z CLP-631z |
IMAJE |
Imaje
5000 Imaje
|
MARKEM |
Markem
9096 (Inkjet printer) |
V8.50.07.01
Manufacturer |
Model |
BRADY |
BBP81 200 BBP81 300 BBP81 600 |
BETAPRINT |
Betaprint 55SST Continuous Betaprint 55SST
Intermittent Betaprint 128SST
Continuous Betaprint 128SST
Intermittent |
V8.50.07
Manufacturer |
Model |
DOMINO |
Domino CM5 Domino IM5 Domino V100 Domino V200 Domino V300+ 2" CM Domino V300+ 2" IM Domino V300+ 5" CM Domino V300+ 5" IM Domino V400 2" Domino V400 5" |
SATO |
CT408i CT412i CT424i |
ZEBRA |
110XiIII Plus UHF (203dpi) 110XiIII Plus UHF (300dpi) 110XiIII Plus UHF (600dpi) 110XiIII Plus HF (203dpi) 110XiIII Plus HF (300dpi) 110XiIII Plus HF (600dpi) |
V8.50.06
Manufacturer |
Model |
SATO |
GL408e GL412e |
V8.50.05
Manufacturer |
Model |
DATAMAX |
M-4206 Mark II M-4210 Mark II |
SATO CX 410 |
Lt408 (RH) Lt408 (LH) MB400i MB410i |
ZEBRA |
ZM400 (203 dpi) ZM400 (300 dpi) ZM600 (203 dpi) ZM600 (300 dpi) |
V8.10.04
Manufacturer |
Model |
DATAMAX Version:
32.03.04 |
DATAMAX H CLASS |
ITW BETAPRINT Version : 32.01.02 |
TP2100 TP4000 |
SATO Version: 31.03.01 |
S8408 (RH) S8408 (LH) S8412 (RH) S8412 (LH) S8424 (RH) S8424 (LH) MB200i |
ZEBRA Version 31.06.00 |
QL 220 Plus
ZPL QL 320 Plus
ZPL QL 420 Plus
ZPL QL 220 Plus
EPL QL 320 Plus
EPL QL 420 Plus EPL |
V8.10.02
Manufacturer |
Model |
DATAMAX Version:
22.24.00 |
DATAMAX H CLASS |
Version |
Ticket ID/ |
Description |
|
|
|
8.51.02 |
|
|
|
34391-16068 |
Excel files with field names that contain Chinese characters were not
working |
|
33780-15966 |
Printouts for DataMatrix/QR code that contain Chinese characters were
not working |
|
32222-15961 |
Barcode wizard could not enter alphabetical characters for DataMatrix |
|
35324-16221 |
WYSIWYG problem with Eltron TLP-3642 |
|
37117-16535 |
Printing with customized pages size is not always properly handled
with Windows drivers |
8.51.01 |
|
|
|
31161-15576 |
Counters with value outside of the alphabet were not accepted at print
time (backward compatibility with version 6) – a warning is displayed at
creation time |
|
29434-15335 |
Lite or Pro versions are no longer able to lock objects. |
|
27277-14994 |
Maxicode wizard did not generate valid default data regardless of selected
mode |
|
32486-15747 |
Display was not correct when using formulas that reference other
formulas |
8.51.00 |
|
|
|
24884-14218 |
Decrementing hexadecimal counter was not decrementing properly |
|
14249-12208 |
Printer speed switch was ignored when printing from SENTINEL |
|
25866-14508 |
EAN-14 can now be based on EAN-128 or ITF-14 symbology |
|
20913-13318 |
Some characters’ descenders were cut off (for example, the bottom
portion of “g”) in Rich Text fields |
|
11697-13708 |
In the Runtime version, the printable or non-printable option for
objects can now be set through ActiveX |
|
|
|
8.50.08 |
|
|
|
24480 - 14121 |
On some configurations, CODESOFT takes longer than usual to start |
|
24947 - 14241 |
Database records were not refreshed before printing using table lookup
data sources |
|
21761 - 14358 |
Empty variables could cause a system crash if using SENTINEL |
|
25468 – 14386 |
Unable to create a graphic barcode EAN13 EXT5 and EXT2 |
|
25472 – 14389 |
Non-printable barcode linked to a data source was printed |
|
25768 – 14491 |
In the Runtime version using ActiveX, the Close method returned an
error |
|
|
|
8.50.07.01 |
|
|
|
00 - 13652 |
Monochrome image with reversed palette does not open in reverse mode |
8.50.07 |
|
|
|
15802 - 12425 |
Labels cannot be modified when in use by SENTINEL TKXPECU |
|
20625 – 13212 |
Database Manager did not work with Excel files |
|
00 - 13097 |
Name of barcode was changed when editing then canceling its properties |
|
00 -
10603 |
Impossible to decrease printer barcode height using down arrow button |
8.50.06 |
|
|
|
15695 - 12400 |
Using date settings, when switching to a
date managed by the printer, the current format is kept if the printer
supports it |
|
00 - 12335 |
Opening a label using the Microsoft Office
Document Image Writer printer may cause the application to crash |
|
17881 - 12801 |
Date and time were not refreshed when
printing a label if Update date during printing option was not set |
|
17895 - 12808 |
Formula counter was not updated when data
was set using the Form |
8.50.05 |
|
|
|
9630 - 11588 |
@labelcpy and @serialqty variables were not
updated in formulas |
|
10386 - 11638 |
SQL warning messages do not display in table
Lookup; only error messages are |
|
9937 - 11605 |
User Manager: new profile was created with
no option |
|
11696 – 11738 |
When the Network connection is broken,
shared variables detect this disconnect |
|
12602 - 11878 |
Upgrades from previous 8.x versions are
fully managed |
|
13024 - 11975 |
Margins were not considered when printing
from SENTINEL (label was always printed with margins set to 0,0 ). |
|
00 - 12178 |
Specific options with barcode are now
available |
|
13214 - 12018 |
Error in transparent background handling is
corrected |
|
13742 - 12105 |
A variable PDF barcode with a non valid data
was displayed on the label and preview but was not printed. |
8.50.04 |
|
|
|
2466 - 11032 |
Paragraph field management is optimized for TEC
printers when using different true type font attributes (size, bold, italic,
etc.) |
|
3118 - 11242 |
Aztec barcode: The pipe character was
misinterpreted |
|
4775 - 11257 |
The movement of empty objects now follows
mouse cursor |
|
6008 - 11379 |
Using Windows 2003 Server with software key
version, the lppa.exe process is now freed from memory when the application
is closed |
|
9107 - 11563 |
Full justified paragraph text causes error
on Windows printer |
|
9109 - 11564 |
When printing with Query result view, if the
database was updated, erroneous data could be printed |
|
9564 - 11584 |
The ActiveX method “Document.Copyimagetofile”
with a negative rotation result with a rotation always set to 45° |
· While installing
CODESOFT on Microsoft Windows 2000 SP4, you may encounter the following error
message: “The procedure entry point HeapSetInformation could not be located in
the dynamic link library KERNEL32.dll.”
CODESOFT includes all the prerequisites required by the product, and
will install the prerequisites when they are not already installed on the
machine. This error occurs when
Microsoft .NET Framework 2.0 SP1 setup fails on Microsoft Windows 2000
SP4. To solve the problem, install the
Security Update for Microsoft Windows, as described in Knowledge Base article
KB835732 at http://support.microsoft.com/.
· Under Windows
Vista SP1, BACKTRACK 6 doesn’t detect CODESOFT. To solve this issue, you have
to start BACKTRACK once using an administrator account.
· When you start
CODESOFT, the application takes longer than usual to start. This is a known
issue identified by Microsoft in Knowledge Base article 936707 at http://support.microsoft.com/. This applies to .NET 2.0 assemblies with
Authenticode signature. This problem
occurs because the affected computer cannot reach the following Microsoft web
site: http://crl.microsoft.com/pki/crl/products/CSPCA.crl.
If the problem occurs, here are two solutions proposed by Microsoft:
- Install Microsoft
.NET 2.0 SP1 or Microsoft
.NET 3.5.
or
- Disable the Check for publisher's
certificate revocation option in Internet Explorer Advanced Options.
· Microsoft
defect with
· Please note
that if using Windows 2008 version, you may need administrator's rights to
perform some actions like adding a printer with non-direct access or creating a
System DSN data source. Please verify that you have sufficient rights
before performing these actions.
· Query definition
only supports tables within the default schema.
If it is necessary to use a table from another schema, the SQL mode
should be used, using a syntax like: SELECT * FROM Schema.Table.
· The Database
Manager is a generic database tool that relies on OLE DB
Provider (ODBC is not supported).
OLE DB Provider or the DBMS itself can both have some limitations. For example, with an Access database, when
you set three unique fields in Database Manager, only the first one will be
set. The recommendation is to use the
internal DBMS tools to modify database structure, especially when working on advanced
actions (like multiple constraints and primary key modification). The same is true for big tables where the
response time can be slow on some operations.
- Document
(*.xmf): |
C:\Documents and Settings\All
Users\Documents\Teklynx\CODESOFT\Samples\Forms |
- Labels: |
C:\Documents and Settings\All
Users\Documents\Teklynx\CODESOFT\Samples\Labels |
- Image: |
C:\Documents and Settings\All
Users\Documents\Teklynx\Common\Images |
· The label version
is guaranteed when using ascending version.
When using a different a version, please check that all versions are in
the same range:
Backward |
CD Masters |
8.00.00 – 8.00.05 |
CS800_XX_R1 CS800_XX_R2_030806 |
8.00.06 – 8.00.08 |
CS800_XX_R2_041206 |
8.00.09 – 8.00.10 |
CS800_XX_R2_080106 CS800_XX_R2_100206 |
8.10.00 – 8.10.02 |
CS800_XX_R3_061212 CS800_XX_R3_061214 CS800_XX_R3_070201 |
8.50.00 |
CS850_XX_R1_070511 |
8.50.01 – 8.50.03 |
CS850_XX_R1_070619 CS850_XX_R4_070713 CS850_XX_R4_070927 |
8.50.04 |
CS850_XX_R4_071120 |
8.50.05 |
CS850_XX_R4_080215 |
8.50.06 |
CS850_XX_R4_080402 |
8.50.07 – 8.50.08 |
CS850_XX_R4_080521 CS850_XX_R4_080620 CS850_XX_R4_080901 |
8.51 |
CS850_XX_R5_081002 |
8.51.01-8.51.02 |
CS850_XX_R5_090126 |
Installation of CODESOFT may upgrade your system with third-party
components and files.
These files are not yet Windows Server 2008 logo compliant; they may
lack some versioning information (like company name or version number), or they
may lack a digital signature.
The list of files that could be added by CODESOFT's installation are
produced by the following companies:
Macromedia for InstallShield items, Veritech and Symbol Technologies,
Inc. for barcode modules, Eastman Kodak and Data Techniques, Inc. for image
modules and Microsoft for Visual C++ items.
File created by InstallShield during install:
C:\Windows\Installer\{206F510A-F0B3-480A-9FDD-9C0EBC8FCAC6}\ARPPRODUCTICON.exe
Files created by Veritech and Symbol Technologies, Inc. for barcode
modules:
C:\Program
Files (x86)\TKI\8\Common\Vericode.dll
C:\Program
Files (x86)\TKI\8\Common\PDFENC32.DLL
Files created by Eastman Kodak and Data Techniques, Inc. for image
modules:
C:\Program
Files (x86)\TKI\8\Common\imgman32.dll
C:\Program
Files (x86)\TKI\8\Common\PCDLIB32.DLL
Components from Microsoft:
C:\Windows\SysWOW64\JETCOMP.exe
C:\Windows\SysWOW64\msexch35.dll
C:\Windows\SysWOW64\msexcl35.dll
C:\Windows\SysWOW64\msjet35.dll
C:\Windows\SysWOW64\msjint35.dll
C:\Windows\SysWOW64\msjt4jlt.dll
C:\Windows\SysWOW64\msjter35.dll
C:\Windows\SysWOW64\msltus35.dll
C:\Windows\SysWOW64\mspdox35.dll
C:\Windows\SysWOW64\msrd2x35.dll
C:\Windows\SysWOW64\msrepl35.dll
C:\Windows\SysWOW64\msrpfs35.dll
C:\Windows\SysWOW64\mstext35.dll
C:\Windows\SysWOW64\msxbse35.dll
C:\Windows\SysWOW64\VBAR332.DLL
C:\Windows\winsxs\x86_microsoft.vc80.atl_1fc8b3b9a1e18e3b_8.0.50727.762_none_11ecb0ab9b2caf3c\ATL80.dll
C:\Windows\winsxs\x86_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.762_none_10b2f55f9bffb8f8\msvcm80.dll
C:\Windows\winsxs\x86_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.762_none_10b2f55f9bffb8f8\msvcp80.dll
C:\Windows\winsxs\x86_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.762_none_10b2f55f9bffb8f8\msvcr80.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfc80.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfc80u.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfcm80.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfcm80u.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80CHS.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80CHT.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80DEU.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80ENU.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80ESP.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80FRA.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80ITA.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80JPN.dll
C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80KOR.dll
Compatibility
with Other TEKLYNX Software
CODESOFT 8.51.02 is compatible and fully tested to
work with the following TEKLYNX software packages:
·
LABEL ARCHIVE 2.06
·
SENTINEL 5.06
·
BACKTRACK 6.0
·
IDEAM 6.0
Copyright
2009 Braton Groupe sarl. All rights
reserved. TEKLYNX and its products are
trademarks or registered trademarks of Braton Groupe sarl or its affiliated
companies. All other brands and product
names are the trademarks of their respective owners.
This
release notes document is for informational purposes only. Product
specifications are likely to change.