RELEASE NOTES - CODESOFT v8.51.02

May 2009

                                                                                          

Table of Contents

 

Windows 2000 SP4
Windows XP SP2, Windows XP SP3
Windows Server 2003
Windows Vista, Windows Vista SP1

Windows Server 2008

Windows x64-bit platform

Installation requires administrator’s privileges.

Back to Top

 

New Features & Enhancements                                                                                                      

New DBCS conversion (v8.51.02)
The QRCode and DataMatrix barcodes now use direct encoding in DBCS instead of using the UnicodeToDBCS formula.

New OCX field (v8.51.02)
This new object type allows you to use a third-party OCX component inside your label.

New formulas (v8.51.02)
New formulas are now available:
Week (calculate week number ISO8601), Extract (extract string from a string), ReplaceString (replace string occurrence(s) with another string)

Space correction for DataMatrix (v8.51.02)
This option allows you to provide space correction between barcode elements.
This can be useful for inkjet printing.

New barcode symbologies (v8.51.01)
Chinese sensible code.
ITF14 supports more option for lines/boxes that surround the code.

New GHS pictograms (v8.51.01)
New pictograms based on GHS normalization are added to the Image Gallery.

New Compliance labels (v8.51.01)
New compliance labels are provided for different areas like Retail, Shipping, Healthcare, and Automotive.

New barcode symbologies (v8.51)
Code 49, Intelligent Mail (USPS 4-State), ISBN-13, and RSS expanded stacked.

New Formulas (v8.51)
New formulas are now available to allow calculation of the “Best before date” and Expiration date at print time:
BestBefore, DateValue, DateOffset

Database loops (v8.51)
It is now possible to specify the number of times a set of records should be printed when using a database.

Refresh table lookup at print time (v8.51)
The Refresh table lookup at print time option allows the system to reevaluate table lookup fields in a document at print time to ensure the most current information is used.

Silent installation (v8.51)
CODESOFT installation can be run in Silent mode, using the basic command line "<Path>\Setup.exe" /s /v"/qn INSTALLLEVEL=150". This command installs CODESOFT in English in the default folder with all features.  For additional parameters, refer to the TEKLYNX web site or the online help.

Pre-requisite installation (v8.51)
CODESOFT pre-requisites (.NET framework 2.0 SP1, MDAC 2.8, Adobe Acrobat Reader 8) are now automatically installed if necessary.

Guides (v8.51)
Quick Start Guide and Administrator’s guide are now directly accessible from the Help menu.

Label Background with image (v8.50.07)

A new Extended tab in Document Properties allows you to define a background.  The user can select an image and different options to define the background that applies to the current label.

OCX Component (v8.50.07)

A new OCX control named “Labeling Manager control” is provided.  This allows easy integration with Microsoft Office applications.

Resolution independent (v8.50.05)

Allows you to design labels that will be printed identically on different printers (office or thermal printers). To access to this option, use the command File > Properties > Preview.

New User interface language (v8.50.05)

Romanian language is now available for the User Interface.

Requery button  (v8.50.05)

A Requery button has been added in the Query result dialog box. This command runs the query and updates the grid.

Windows graphical emulation (v8.50.04)

Enables you to standardize printing of your labels irrespective of the printer selected (Thermal printers or Windows printers). Use the command File > Properties > Preview to access this option.

Wizard Upgrade tool (v8.50.02)

This tool eases updates from CODESOFT 8 to CODESOFT 8.5.  It allows you to transfer the settings and files from the previous version to the new one.  You can launch it from C:\Program Files\TKI\8\Common\Tools\WizardUpgrade\UpgradeWizard.exe.

New Wizards (v8.50)

New wizards ease the creation of:
- Documents
- Objects, such as Text, Barcode, and Image
- Variables like Counter, Form, Free, and Date.

The wizards can be activated and deactivated individually.

Enhanced menu look and feel (v8.50)

A new look and feel for menus is now available. This is similar to what is available in Office 2003.  Two themes are available.

Enhanced Open dialog box (v8.50)

The new open look and feel for the Open dialog box is used.  This provides the left toolbar icons with direct access to some pre-defined folders.

Enhanced Print dialog box (v8.50)

The Print dialog box now includes several tabs when expanded.
This will allow you to check, based on current print settings (number of labels, pages, etc.) whether printing is optimized using the Performance tab.

Text Vertical alignment (v8.50)

This option allows you to define a vertical alignment for text paragraph.  This option is only available with the Fit to frame option.

Text on any angle (v8.50)

In the Shape Settings tab, the Polyline shape option allows the user to select any kind of shape.
This option can be very useful in conjunction with a text art to position text on any angle.
 

Label Background definition (v8.50)

It is now possible to select a label background without having to use a name based on the stock type/name.

A new Background combo box allows you to select the EMF/WMF file that will be used as the label background.
The EMF/WMF files need to be published in the C:\Program Files\TKI\8\Common\LFM directory.

Network licensing (v8.50)

A new range is available through Network licensing: Runtime.

For License Manager, the Shared folder is changed.

On Vista, you must share "C:\Programdata\TKI\LicenseManager\TkDongle" as "TkDongle" and on the other systems you must share "C:\Documents and Settings\All Users\Application Data\TKI\LicenseManager\TkDongle" as "TkDongle."

Folder reorganization (v8.50)

Here is the description of the new folder reorganization.

Samples & Tutorial

 

Sample Labels

<All Users Profile>\Documents\Teklynx\CODESOFT\Sample\Labels

Sample Forms

<All Users Profile>\Documents\Teklynx\CODESOFT\Sample\Forms

Sample Compliance

<All Users Profile>\Documents\Teklynx\CODESOFT\ Sample\Compliance

Tutorial

<All Users Profile>\Documents\Teklynx\CODESOFT\Tutorial

Common files

 

Data files (including databases)

<All Users Profile>\Documents\Teklynx\Common\Data

Describers

<All Users Profile>\Documents\Teklynx\Common\DSC

Specific Formulas

<All Users Profile>\Documents\Teklynx\Common\Formulas

Image Gallery

<All Users Profile>\Documents\Teklynx\Common\Galleries

Images

<All Users Profile>\Documents\Teklynx\Common\Images

Patterns

<All Users Profile>\Documents\Teklynx\Common\Patterns

Queries

<All Users Profile>\Documents\Teklynx\Common\Query

Shapes

<All Users Profile>\Documents\Teklynx\Common\Shapes

Print files

<All Users Profile>\Documents\Teklynx\Print

Application configuration files

(Files created by the application and its tools/add-ons)

Shared variables files

<CommonAppData>\Teklynx\System\Globvar

Network printers settings

<CommonAppData>\Teklynx\System\Printers

Product config files (user.ini and user.bar)

<CommonAppData>\Teklynx\System\<ProductRange>

<ProductRange> is the range of the product; for example, Enterprise, Pro, or Lite.


Superimposing (v8.10)

This is an optional feature that allows you to superimpose objects to preserve the readability or physical space on the label.  This feature is useful when using a barcode to prevent any other object from being overlaid on top of it.  This feature can be enabled by going to the General tab of the object’s properties.

Norm GS1 (v8.10)

Choosing to use the GS1 norm enables barcode verifications according to GS1 (formerly EAN) recommendations.
This new option is available in Tools > Options dialog box > Others tab.  When the option is enabled, it will check that the barcodes conform to the different requirements of the GS1 normalization, such as narrow bar size, check digit, and human-readable.

RFID (v8.10)

A new RFID button, available on the toolbar, provides a direct link to the RFID settings.

TKTEXTIL.TTF (v8.10)

New symbols have been added in TKTextil.ttf to fulfill the COFREET requirements.  Refer to the TKTextil.lab sample file.

Database Manager (v8.10)

The User Interface of the Database Manager has been improved making it more intuitive and easy to use.

  • The general user interface has been refreshed to give it a better look and feel.
  • A new menu entry (File > Open) allows the user to directly open a basic database file (Access, Excel, dBase).
  • It is now possible to create duplicate record(s) with a single right-click on selected records.
  • More feedback is provided to the user when operations cannot be performed (limited user rights, not compliant with database structure, etc.).
  • It is possible to limit the Database Manager features by modifying the file C:\Program Files\TKI\8\Common\Tools\DMan\ProductSettings.cfg. (Note: This feature is for advanced users only.)
  • It is now possible to customize the display font.

Print by printer resolution (v8.10)

Uses an algorithm independent to the paper format, to send only the positions and sizes linked to the Windows printer’s resolution.
The current print algorithm adjusts object size and position when you switch, for instance, from a A4 page to Letter page (on a Windows printer).  This is similar to the method used in Microsoft Word, and the advantage is that the objects are adjusted at print time so that everything fits on the page/label.  The new print algorithm only uses the printer resolution, which means that the object’s position and size are fixed, but at print time, you may notice that some objects are outside the page/label or partially cut.

ActiveX

VC++ and C# ActiveX samples available on CD have been updated to demonstrate how to use Events. 

 Back to Top

New Device Support                                                                                    

 

The following devices and their associated drivers have been added in this version:

V8.51.02

Manufacturer

Model

 BRADY

BRADY BBP11-24L
BRADY BBP11-34L

INTERMEC

EasyCoder PD42 DP (203dpi)

EasyCoder PD42 DP (300dpi)

EasyCoder PD42 IPL (203dpi)

EasyCoder PD42 IPL (300dpi)

EasyCoder PD42 FP mode (203dpi)

EasyCoder PD42 FP mode (300dpi)
PB21 IPL mode (203dpi)
PB22 IPL mode (203dpi)
PB31 IPL mode (203dpi)
PB32 IPL mode (203dpi)
PB21 DP mode (203dpi)
PB22 DP mode (203dpi)
PB31 DP mode (203dpi)
PB32 DP mode (203dpi)
PB21 FP mode (203dpi)
PB22 FP mode (203dpi)
PB31 FP mode (203dpi)
PB32 FP mode (203dpi)
Intermec PF8d
Intermec PF8t (203dpi)
Intermec PF8t (300dpi)
PB50 FP mode (203dpi)
PB50 DP mode (203dpi)
PB50 IPL mode (203dpi)
PB51 DP mode (203dpi)
PB51 FP mode (203dpi)

PB51 IPL mode (203dpi)

V8.51.01

Manufacturer

Model

 BROTHER

Brother MW-140BT

Brother MW-260

Brother QL-1060N

Brother RL-700S

COGNITIVE

Cognitive AdvantageDLX DBD24-2085-xxx

Cognitive AdvantageDLX DBT24-2085-xxx

Cognitive AdvantageDLX DBD42-2085-xxx

Cognitive AdvantageDLX DBT42-2085-xxx

TALLYGENICOM

TallyGenicom 7005 DT2 (203dpi)

TallyGenicom 7005 DT4 (203dpi)

TallyGenicom 7005 TT4 (203dpi)

ZEBRA

Zebra GK420d EPL

Zebra GK420t EPL

Zebra GX420d EPL

Zebra GX420t EPL

Zebra GX430t EPL

Zebra GK420d ZPL

Zebra GK420t ZPL

Zebra GX420d ZPL

Zebra GX420t ZPL

Zebra GX430t ZPL

VIDEOJET

VIDEOJET VJ2310

VIDEOJET VJ2320

VIDEOJET VJ2330

ICE

ICE Torus 126

ICE Torus 380

ICE Torus 500

MARSH

Marsh 1100

Marsh 2100

Marsh 3100

LINX

Linx IJ350

Linx IJ370

V8.50.08

Manufacturer

Model

 TALLYGENICOM

TallyGenicom MTP4P

TallyGenicom MTP4P EPL

TallyGenicom MTP4P ZPL

TallyGenicom 7006 DT2 (203dpi)

TallyGenicom 7006 DT2 (300dpi)

TallyGenicom 7006 DT4 (203dpi)

TallyGenicom 7006 DT4 (300dpi)

TallyGenicom 7006 TT2 (203dpi)

TallyGenicom 7006 TT2 (300dpi)

TallyGenicom 7006 TT4 (203dpi)

TallyGenicom 7006 TT4 (300dpi)

TallyGenicom 7008 DT2 (203dpi)

TallyGenicom 7008 DT2 (300dpi)

TallyGenicom 7008 DT4 (203dpi)

TallyGenicom 7008 DT4 (300dpi)

TallyGenicom 7008 TT2 (203dpi)

TallyGenicom 7008 TT2 (300dpi)

TallyGenicom 7008 TT4 (203dpi)

TallyGenicom 7008 TT4 (300dpi)

 BRADY          

Brady BBP81 200

Brady BBP81 300

Brady BBP81 600

 ZEBRA

MZ 200

MZ320

Zebra RW 220 ZPL

Zebra RW 420 ZPL

Zebra RW 220 EPL

Zebra RW 420 EPL

Zebra RW 220

Zebra RW 420

 CITIZEN          

CLP-521z

CLP-621z

CLP-631z

IMAJE

Imaje 5000 53 mm

Imaje 5000 107 mm

MARKEM

Markem 9096 (Inkjet printer)

V8.50.07.01

Manufacturer

Model

 BRADY

BBP81 200

BBP81 300

BBP81 600

 BETAPRINT

Betaprint 55SST Continuous

Betaprint 55SST Intermittent

Betaprint 128SST Continuous

Betaprint 128SST Intermittent

V8.50.07

Manufacturer

Model

 DOMINO

Domino CM5

Domino IM5

Domino V100

Domino V200

Domino V300+ 2" CM

Domino V300+ 2" IM

Domino V300+ 5" CM

Domino V300+ 5" IM

Domino V400 2"

Domino V400 5"

 SATO

CT408i

CT412i

CT424i

 

 ZEBRA

110XiIII Plus UHF (203dpi)

110XiIII Plus UHF (300dpi)

110XiIII Plus UHF (600dpi)

110XiIII Plus HF   (203dpi)

110XiIII Plus HF   (300dpi)

110XiIII Plus HF   (600dpi)

 

 

 

V8.50.06

Manufacturer

Model

 SATO

GL408e

GL412e

 

 

 

V8.50.05

Manufacturer

Model

 DATAMAX

 M-4206 Mark II

 M-4210 Mark II

 

 SATO CX 410

Lt408 (RH)

Lt408 (LH)

MB400i

MB410i

 

 ZEBRA

 ZM400 (203 dpi)

 ZM400 (300 dpi)

 ZM600 (203 dpi)

 ZM600 (300 dpi)

 

 

 

V8.10.04

Manufacturer

Model

 DATAMAX

 Version: 32.03.04

 

 DATAMAX H CLASS

 

 ITW BETAPRINT 

 Version : 32.01.02

TP2100

TP4000

 

 SATO

 Version: 31.03.01

S8408 (RH)

S8408 (LH)

S8412 (RH)

S8412 (LH)

S8424 (RH)

S8424 (LH)

MB200i

 

 ZEBRA

 Version 31.06.00

QL 220 Plus ZPL

QL 320 Plus ZPL

QL 420 Plus ZPL

QL 220 Plus EPL

QL 320 Plus EPL

QL 420 Plus EPL      

 

 

 

V8.10.02

Manufacturer

Model

 DATAMAX

 Version: 22.24.00

 

 DATAMAX H CLASS

 

 

 

                         

             back to top

 

 

Version

Ticket ID/
Defect ID

Description

 

 

 

8.51.02

 

 

 

34391-16068

Excel files with field names that contain Chinese characters were not working

 

33780-15966

Printouts for DataMatrix/QR code that contain Chinese characters were not working

 

32222-15961

Barcode wizard could not enter alphabetical characters for DataMatrix

 

35324-16221

WYSIWYG problem with Eltron TLP-3642

 

37117-16535 

Printing with customized pages size is not always properly handled with Windows drivers

8.51.01

 

 

 

31161-15576

Counters with value outside of the alphabet were not accepted at print time (backward compatibility with version 6) – a warning is displayed at creation time

 

29434-15335

Lite or Pro versions are no longer able to lock objects.

 

27277-14994

Maxicode wizard did not generate valid default data regardless of selected mode

 

32486-15747

Display was not correct when using formulas that reference other formulas

8.51.00

 

 

 

24884-14218

Decrementing hexadecimal counter was not decrementing properly

 

14249-12208

Printer speed switch was ignored when printing from SENTINEL

 

25866-14508

EAN-14 can now be based on EAN-128 or ITF-14 symbology

 

20913-13318

Some characters’ descenders were cut off (for example, the bottom portion of “g”) in Rich Text fields

 

11697-13708

In the Runtime version, the printable or non-printable option for objects can now be set through ActiveX

 

 

 

8.50.08

 

 

 

24480 - 14121

On some configurations, CODESOFT takes longer than usual to start

 

24947 - 14241

Database records were not refreshed before printing using table lookup data sources

 

21761 - 14358

Empty variables could cause a system crash if using SENTINEL

 

25468 – 14386

Unable to create a graphic barcode EAN13 EXT5 and EXT2

 

25472 – 14389

Non-printable barcode linked to a data source was printed

 

25768 – 14491

In the Runtime version using ActiveX, the Close method returned an error

 

 

 

8.50.07.01

 

 

 

00 - 13652

Monochrome image with reversed palette does not open in reverse mode

8.50.07

 

 

 

15802 - 12425

Labels cannot be modified when in use by SENTINEL TKXPECU

 

20625 – 13212

Database Manager did not work with Excel files

 

00 - 13097

Name of barcode was changed when editing then canceling its properties

 

00 - 10603

Impossible to decrease printer barcode height using down arrow button

8.50.06

 

 

 

15695 - 12400

Using date settings, when switching to a date managed by the printer, the current format is kept if the printer supports it

 

 00 - 12335

Opening a label using the Microsoft Office Document Image Writer printer may cause the application to crash

 

17881 - 12801

Date and time were not refreshed when printing a label if Update date during printing option was not set

 

17895 - 12808

Formula counter was not updated when data was set using the Form

8.50.05

 

 

 

9630 - 11588

@labelcpy and @serialqty variables were not updated in formulas

 

10386 - 11638

SQL warning messages do not display in table Lookup; only error messages are

 

9937 - 11605

User Manager: new profile was created with no option

 

11696 – 11738

When the Network connection is broken, shared variables detect this disconnect

 

12602 - 11878

Upgrades from previous 8.x versions are fully managed

 

13024 - 11975

Margins were not considered when printing from SENTINEL (label was always printed with margins set to 0,0 ).

 

00 - 12178

Specific options with barcode are now available

 

13214 - 12018

Error in transparent background handling is corrected

 

13742 - 12105

A variable PDF barcode with a non valid data was displayed on the label and preview but was not printed.  

8.50.04

 

 

 

2466 - 11032

Paragraph field management is optimized for TEC printers when using different true type font attributes (size, bold, italic, etc.)

 

3118 - 11242

Aztec barcode: The pipe character was misinterpreted
The management of multiple symbols is now allowed

 

4775 - 11257

The movement of empty objects now follows mouse cursor

 

6008 - 11379

Using Windows 2003 Server with software key version, the lppa.exe process is now freed from memory when the application is closed

 

9107 - 11563

Full justified paragraph text causes error on Windows printer

 

9109 - 11564

When printing with Query result view, if the database was updated, erroneous data could be printed

 

9564 - 11584

The ActiveX method “Document.Copyimagetofile” with a negative rotation result with a rotation always set to 45°

back to top

Known Limitations                                                                                                  

·       While installing CODESOFT on Microsoft Windows 2000 SP4, you may encounter the following error message: “The procedure entry point HeapSetInformation could not be located in the dynamic link library KERNEL32.dll.”  CODESOFT includes all the prerequisites required by the product, and will install the prerequisites when they are not already installed on the machine.  This error occurs when Microsoft .NET Framework 2.0 SP1 setup fails on Microsoft Windows 2000 SP4.  To solve the problem, install the Security Update for Microsoft Windows, as described in Knowledge Base article KB835732 at http://support.microsoft.com/.

·       Under Windows Vista SP1, BACKTRACK 6 doesn’t detect CODESOFT. To solve this issue, you have to start BACKTRACK once using an administrator account.

·       When you start CODESOFT, the application takes longer than usual to start. This is a known issue identified by Microsoft in Knowledge Base article 936707 at http://support.microsoft.com/.  This applies to .NET 2.0 assemblies with Authenticode signature.  This problem occurs because the affected computer cannot reach the following Microsoft web site: http://crl.microsoft.com/pki/crl/products/CSPCA.crl.

If the problem occurs, here are two solutions proposed by Microsoft:
- Install Microsoft .NET 2.0 SP1 or Microsoft .NET 3.5.
or
- Disable the Check for publisher's certificate revocation option in Internet Explorer Advanced Options.

·       Microsoft defect with Vista: When you upgrade from a previous version of CODESOFT 8.5, the Windows installer does not always install MFC8 modules. We recommend uninstalling the previous version of CODESOFT before installing the new one. If you have already installed CODESOFT and it does not start, you can solve the problem by installing the MFC8 modules using the Microsoft redistributable vcredist_x86.exe. This redistributable is provided on the CODESOFT CD (under Software\Misc\vcredist_x86) or can be downloaded from the Microsoft web site.

·       Please note that if using Windows 2008 version, you may need administrator's rights to perform some actions like adding a printer with non-direct access or creating a System DSN data source. Please verify that you have sufficient rights before performing these actions.

·       Query definition only supports tables within the default schema.  If it is necessary to use a table from another schema, the SQL mode should be used, using a syntax like: SELECT * FROM Schema.Table.

·       The Database Manager is a generic database tool that relies on OLE DB Provider (ODBC is not supported).  OLE DB Provider or the DBMS itself can both have some limitations.  For example, with an Access database, when you set three unique fields in Database Manager, only the first one will be set.  The recommendation is to use the internal DBMS tools to modify database structure, especially when working on advanced actions (like multiple constraints and primary key modification).  The same is true for big tables where the response time can be slow on some operations.

  • The sample forms designed to demonstrate the Form Designer and Form Viewer need to have the following folder selection in order to work (the default path set during installation).  This folder selection can be modified in Tools > Options > Default Folders tab.  

- Document (*.xmf):

C:\Documents and Settings\All Users\Documents\Teklynx\CODESOFT\Samples\Forms

- Labels:

C:\Documents and Settings\All Users\Documents\Teklynx\CODESOFT\Samples\Labels

- Image:

C:\Documents and Settings\All Users\Documents\Teklynx\Common\Images

 

 

 

  • A database connection must be linked to the DatabaseGrid control displayed in sample form DBForm.xmf in order to show information (for example, identity.mdb).  

  • Microsoft defect: MFC Applications leak GDI objects on computer running Windows Server 2003 or Windows XP.  Refer to article 319740 in the Microsoft Knowledge Base: http://support.microsoft.com/.

  • For fully Chinese-sensible code support under winXP\2003\2000 following prerequisites are required:
    - GB18030 support package should be installed: http://www.microsoft.com/downloads/details.aspx?familyid=fc02e2e3-14bb-46c1-afee-3732d6249647&displaylang=en.
    - Files for East Asian languages should be installed.
    For Windows XP/2003: 54936 Gb18030 Simplified Chinese codepage should be selected.
    Note that for Windows 2000, selection of 936 codepage is enough.

·      The label version is guaranteed when using ascending version.  When using a different a version, please check that all versions are in the same range:

Backward Compatibility Range

                         CD Masters

8.00.00 – 8.00.05

CS800_XX_R1
CS800_XX_R2
CS800_XX_R2_121605
CS800_XX_R2_010606
CS800_XX_R2_020106

CS800_XX_R2_030806

8.00.06 – 8.00.08

CS800_XX_R2_041206
CS800_XX_R2_052206
CS800_XX_R2_062906

8.00.09 – 8.00.10

CS800_XX_R2_080106

CS800_XX_R2_100206

8.10.00 – 8.10.02

CS800_XX_R3_061212

CS800_XX_R3_061214

CS800_XX_R3_070201

8.50.00

CS850_XX_R1_070511

8.50.01 – 8.50.03

CS850_XX_R1_070619

CS850_XX_R4_070713

CS850_XX_R4_070927

8.50.04

CS850_XX_R4_071120

8.50.05

CS850_XX_R4_080215

8.50.06

CS850_XX_R4_080402

8.50.07 – 8.50.08

CS850_XX_R4_080521

CS850_XX_R4_080620

CS850_XX_R4_080901

8.51

CS850_XX_R5_081002

8.51.01-8.51.02

CS850_XX_R5_090126
CS850_XX_R5_090206
CS850_XX_R5_090519

  back to top

 

Installation of CODESOFT may upgrade your system with third-party components and files.

These files are not yet Windows Server 2008 logo compliant; they may lack some versioning information (like company name or version number), or they may lack a digital signature.

The list of files that could be added by CODESOFT's installation are produced by the following companies:  Macromedia for InstallShield items, Veritech and Symbol Technologies, Inc. for barcode modules, Eastman Kodak and Data Techniques, Inc. for image modules and Microsoft for Visual C++ items.

File created by InstallShield during install:

C:\Windows\Installer\{206F510A-F0B3-480A-9FDD-9C0EBC8FCAC6}\ARPPRODUCTICON.exe

Files created by Veritech and Symbol Technologies, Inc. for barcode modules:

C:\Program Files (x86)\TKI\8\Common\Vericode.dll

C:\Program Files (x86)\TKI\8\Common\PDFENC32.DLL

Files created by Eastman Kodak and Data Techniques, Inc. for image modules:

C:\Program Files (x86)\TKI\8\Common\imgman32.dll

C:\Program Files (x86)\TKI\8\Common\PCDLIB32.DLL

Components from Microsoft:

C:\Windows\SysWOW64\JETCOMP.exe

C:\Windows\SysWOW64\msexch35.dll

C:\Windows\SysWOW64\msexcl35.dll

C:\Windows\SysWOW64\msjet35.dll

C:\Windows\SysWOW64\msjint35.dll

C:\Windows\SysWOW64\msjt4jlt.dll

C:\Windows\SysWOW64\msjter35.dll

C:\Windows\SysWOW64\msltus35.dll

C:\Windows\SysWOW64\mspdox35.dll

C:\Windows\SysWOW64\msrd2x35.dll

C:\Windows\SysWOW64\msrepl35.dll

C:\Windows\SysWOW64\msrpfs35.dll

C:\Windows\SysWOW64\mstext35.dll

C:\Windows\SysWOW64\msxbse35.dll

C:\Windows\SysWOW64\VBAR332.DLL

C:\Windows\winsxs\x86_microsoft.vc80.atl_1fc8b3b9a1e18e3b_8.0.50727.762_none_11ecb0ab9b2caf3c\ATL80.dll

C:\Windows\winsxs\x86_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.762_none_10b2f55f9bffb8f8\msvcm80.dll

C:\Windows\winsxs\x86_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.762_none_10b2f55f9bffb8f8\msvcp80.dll

C:\Windows\winsxs\x86_microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.762_none_10b2f55f9bffb8f8\msvcr80.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfc80.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfc80u.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfcm80.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_0c178a139ee2a7ed\mfcm80u.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80CHS.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80CHT.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80DEU.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80ENU.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80ESP.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80FRA.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80ITA.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80JPN.dll

C:\Windows\winsxs\x86_microsoft.vc80.mfcloc_1fc8b3b9a1e18e3b_8.0.50727.762_none_43efccf17831d131\mfc80KOR.dll

 

 Back to Top

Compatibility with Other TEKLYNX Software

 

CODESOFT 8.51.02 is compatible and fully tested to work with the following TEKLYNX software packages:

·        LABEL ARCHIVE 2.06

·        SENTINEL 5.06

·        BACKTRACK 6.0

·        IDEAM 6.0

 

Back to Top

 

Copyright 2009 Braton Groupe sarl.  All rights reserved.  TEKLYNX and its products are trademarks or registered trademarks of Braton Groupe sarl or its affiliated companies.  All other brands and product names are the trademarks of their respective owners.

This release notes document is for informational purposes only. Product specifications are likely to change.

 

 

A new easy-to-use software that lets you view pre-defined forms